CMC/SCC fail to push upgrade images to FIPS mode SteelHead running 9.6.0 and 9.6.0a .

Solution Number:
S30558
Last Modified:
2017-05-04
Issue
CMC/SCC fail to push upgrade images to FIPS mode SteelHead running 9.6.0 and 9.6.0a. This will prevent Steelhead upgrades from 9.6.0+, to future versions, using the SCC.
Solution
This is a known issue tracked as Bug#282285. In summary due to this bug, ssh client and sshd server running on these boxes may negotiate FIPS-disallowed cipher curve25519. FIPS closes such connection resulting in connection failure. Fix for this bug will be included RiOS 9.6.0b (ETA 1st week of June, 2017).

Workaround: Disable FIPS on steelhead during RiOS upgrade from SCC/CMC.

Fix it by upgrading to RiOS 9.6.0b.(ETA 1st week of June, 2017)

 
Environment
RiOS 9.6.0 and 9.6.0a
Attachments
NOTICE: Riverbed® product names have changed. Please refer to the Product List for a complete list of product names.
Can't find an answer? Create a case