Inconsistent data when retreiving historical data with Dashboards.

Solution Number:
S24554
Last Modified:
2014-09-12
Issue

If you have issues and inconsisent data when retreiving historical data with Dashboards and you are using: 
client  2.3 PL1 Dashboard connected to a
9.0 SMP which has all 8.5.1 DSAs.

The issue may be due to version incompatibility with SMP 9.0 and DSA 8.5.
DSA 8.5 only sees 15 minutes of 1-second data before the data becomes unavailable.

Solution

Use 15 minutes (900 seconds) for MaxOneSecondDataStorage for DSA 8.5.
In <AIX 9.0>\hedzup\smp\config\webdashboards\DashboardConfiguration.properties file, edit and change to:
MaxOneSecondDataStorage=900

Environment

SteelCentral RPM Dashboards

SteelCentral AppInternals

Attachments