Fiber Specification for 10G LR NIC

Solution Number:
S17798
Last Modified:
2022-10-06
Issue

What are the operating specifications for the 2 Port 10GbE Singlemode Fiber PCI Express Bypass Card (410-00301-01 NIC-10G-2LR)?

Solution

Operating specifications for the 2 port 10GbE Singlemode (LR) Fiber interface card:

Feature Support

Feature  Info   Software Versions  Notes
Fail to Wire Yes All  
Fail to Block Yes All Hardware has full fail to block support.
 Jumbo Frames  Yes    Maximum Ethernet packet size must be configured 

 

Supported Platforms

 Platform   Models 
 1UABA  Steelhead: 1050, 2050
 3UABA  Steelhead 5050, 6050, 7050; Interceptor 9350 

 

Supported Software Versions

 Product   Minimum Supported Versions 
 Steelhead  6.0.2 , 5.5.8
 Interceptor  2.0.4: Supports UDP and TCP hardware pass-through rules

 

LED Specifications

 LED Link/Activity   Quantity: 2 LEDs per port
 Yellow: Turns on link
 Green: Blinks on activity
 Bypass  Green: turns on when system is powered and in bypass 
 Yellow: Disconnect
 Off: Normal

 

Technical Specifications

Mfg/Eng Part Number  410-00301-01
  Orderable Part Number   NIC-10G-2LR
Connectors  2 Small Form Factor (SFF) LC fiber connectors
Board Size  6.60 X 4.2 inches (167.64mm X 106.68mm)
Holder  Metal Bracket, Full Height
Weight  11.2oz (320 grams)
Power Consumption  24.2W, 1.6A at 12V and 1.5A at 3.3V: Typical with 2 ports operating at 10Gbps
Operating Humidity  0%-90%, non-condensing
Operating Temperature  0C to 50C (32F to 122F)
Storage Temperature  -20C to 65C (-4F to 149F)
Ethernet Chip  Intel 82598EB
Linux Driver  ixgbe

 

Fiber Gigabit Ethernet Specifications 10GBase-LR

IEEE Standard / Network topology  Fiber 10Gigabit Ethernet, 10GBase-LR (1310 nM)
  Cables and Operating distance (Up to)   Singlemode fiber: 9u, Max 5 km
  ** Theoretical Distance - Defined as half a distance as specified in the optical transceiver
Optical Output Power  Normal Mode (Bypass Off)
  Typical: -2.3 dBm (TX - Switch Normal - Fiber - LC/LC)
  Maximum: -0.1 dBm
  Minimum: -9.8 dBm
Optical Input Power   Normal Mode (Bypass Off)
  Maximum power (Rx Overload): +1.1 dBm
  Minimum power (Rx Sensitivity): -11.0 dBm
Insertion Loss  Bypass Mode:
  Insertion loss (Optical Power attenuation between TX to RX)
  Maximum 1.8dB
Baud Rate  10.3125GBd
Environment

Steelhead
Interceptor

Attachments
NOTICE: Riverbed® product names have changed. Please refer to the Product List for a complete list of product names.
Can't find an answer? Create a case